美国CIRS 036A-CVXX-XX放疗测试体模

  • 这真不是您需要的产品?
  • 品  牌:
  • 美国CIRS
  • 主要规格:
  • 美国CIRS 036A-CVXX-XX放疗测试体模
  • 用  途:
  • 美国CIRS 036A-CVXX-XX放疗测试体模
    • 美国CIRS 036A-CVXX-XX放疗测试体模,CIRS 036A-CVXX-XX体模,036A-CVXX-XX模体详细描述

       美国CIRS 036A-CVXX-XX放疗测试体模,CIRS 036A-CVXX-XX体模,036A-CVXX-XX模体简介:

      The high dose per fraction associated with SBRT necessitates a high degree of accuracy in target localization and dose delivery.  Small errors can result in significant under treatment of portions of the tumor volume and over dosages of nearby normal tissues. The E2E® SBRT Phantom provides a means to check the entire treatment chain during commissioning and routine QA.

      The Model 036A-CVXX-xx* is an anthropomorphic thorax body containing articulated spine, ribs, and lungs. All materials are suitable for use in kV and MV energies.

      The thorax section contains two lung tumor volumes with ionization chamber cavities in the center of each target*. The phantom also includes a lung insert with a kidney-shaped lung target. The proximity of the lung target to the vertebral body allows clinicians to measure high-resolution dose distribution to the target and dose to the spinal chord in a single delivery. An axial slice of the thorax enables high resolution dose distribution measurements to the vertebral body and vertebral chord. Ready-cut films with integral registration holes are available for both the lung insert and axial slice.






       

      The surface of the thorax body is machined with concentric circle targets, point targets and alignment marks for daily system checks.

      An optional abdominal section (Model 036-01) with 3D spine anatomy for Gapchronic Film and nanoDot™ dosimetry is available separately. It can also accommodate the CBCT Image Quality phantom (Model 062QA-35). The Model 036-01 provides extra bolus to allow non-coplanar dose assessments with the thorax.

      The SBRT phantom is a single tool for end-to-end localization assessment and dosimetric evaluation for use on both SRS Frame-based and IGRT systems.
       

      美国CIRS 036A-CVXX-XX放疗测试体模特点:

      • Thorax with articulated spine, ribs and lungs

      • Optional Abdomen with Gafchromic Film insert

      • High Resolution Anthropomorphic Characteristics

      • Center point fiducial and offset target for daily system checks

      • Succinct tool for commissioning an SBRT program

      • Excellent test environment for Monte Carlo dose calculation verification

      • Supports use and testing of Image Guidance capabilities

      • Facilitates SBRT planning and delivery for Lung, Liver, and Spine treatments

       

      *NOTE: This product or an optional accessory of this product requires a CIRS dosimetry cavity code before an order can be placed. Please refer to the Dosimetry Cavity Codes document to identify the CIRS code for the probe you intend to use with this product.